Digital Day/Night Humidity Controller
Model: HC-210(Cannot sell to Australia)
Features:
- Blue tape LCD display, simple operation
- Stable imported humicap sensor, humidity adjusted per 0.1%
- Two timers can be set during 24 hours
- Uses a inbuilt real-time clock to control the light so simulating the day and night as in the real environment
- Can be set with a separate day and night humidity
- Two kinds of humidity alarms, mute function available
- Can be used in both wet and dry environments
- Backlight auto shut down if without operation for 10 minutes
- Small in size making it stylish and discrete
Parameters:
- Humidification and dehumidification mode switchable
- Controlling range: 0.0~99.9%
- Measuring range: 0.0~99.9%
- Resolution: 0.1%; Accuracy: ±5.0%
- Over humidity alarm: 0.0-20.0%(can be modified)
- Humidity differential: 0.0-10.0%
- Time unit: hour (24:00 format)
- Relay Capacity: 10A or custom
- Input voltage: 220VAC±15%,50/60HZ(Optional:110VAC)
- Product consumption: ≤3W
- Control load: ≤1200W/220VAC
- Two independent sockets –First socket (nearest power cable) is for humidification or dehumidification output; Second socket is for the timer output (for lighting for example). Optional: EU, USA, UK or other type
Package Included:
- 1 x thermostat(power strip included)
- 1 x user manual
Menu instructions:
Menu item
|
Set
|
Default value
|
Remark
|
MODE
|
HUMI/DEHUMI
|
HUMI
|
|
Daytime Humidity(SET)
|
0.0~99.9%
|
50%
|
Adjusted per 0.1%
|
Nighttime Humidity(SET)
|
0.0~99.9%
|
50%
|
Adjusted per 0.1%
|
Humidity differential
|
0.0~10.0%
|
5.0%
|
Adjusted per 0.1%
|
Alarm variation humidity
|
0.0~20.0%
|
10.0%
|
Adjusted per 0.1%
|
DAY FROM
|
00:00—22:59
|
08:00
|
|
NIGHT FROM
|
01:00—23:59
|
18:00
|
If NIGHT FROM time is earlier than DAY FROM time, display error message "ERR".
|
1stTiming control (TIMER1):
ON: FROM, OFF: TO
|
00:00~23:59
|
00:00~06:00
|
Disabled if FROM and TO are same
|
2nd Timing control (TIMER2):
ON: FROM, OFF: TO
|
00:00~23:59
|
12:00~18:00
|
Disabled if FROM and TO are same
|
CLOCK
|
00:00~23:59
|
Real-time
|
24 Hour Clock
|
Symbol:
Icon visible; flashing: Humidification output; Icon visible; flashing: Dehumidification output;
Icon visible; flashing: Timer1 output; Icon visible; flashing: Timer2 output;
Icon daytime visible; Icon nighttime visible;
Icon invisible; flashing:alarm over humidity; Icon visible; flashing: clock setting;
Button:
: Save; : Up; : Down; : Set
General Setting Note:
- Parameters of humidity and timers can be viewed by pressing UP or DOWN key in normal status.
- If you do not complete a setting and the unit is left and settings are not saved, the product returns to default settings automatically if no key is operated within 15 seconds.
Upper and lower humidity limits setting:
You can set a limit to the humidity range that your controller operates at. The default is between 0.0~99.9% but you can reduce this range. To do this, in normal working status:
- Highest humidity limit setting: Press UP button for 5 seconds to display default upper humidity limit settings and then press UP or DOWN button to modify the set value.
- Lowest humidity limit setting: Press DOWN button for 5 seconds to display default lower humidity limit settings and then press UP or DOWN button to modify the set value.
Humidity alarming:
There are three humidity alarms. The first is for when the humidity exceeds the set ‘TEMP ALARM’ selected earlier. The unit will beep and the alarm icon flashes in the below situations:
- The measured humidity ≥ the set humidity + Alarm variation humidity
- The measured humidity ≤ the set humidity – Alarm variation humidity
The second alarm is for if the probe has an open or short circuit. The unit will display an error message for the probe fault ‘ERR’ and the alarm will sound.
Mute alarming manually:
- When an over humidity alarm sounds, you can press any key to mute this. However, a probe fault alarm sound cannot be muted.
- You can set whether you have the alarm on or off. Press UP and DOWN at the same time for 3 seconds. The option becomes available to choose whether to turn the alarm sound on or off. AL: Alarm sound on, NO: No alarm sounds. Choose the option you require by using the UP or DOWN button and Press SAVE button to finish and exit.
Friedly Reminder:
- We can provide customized service for all of our products with reasonable price.
Applications:
1. Refrigeration industry(freezers, refrigerators, , Cold stores, cold chain, iceboxes, cooling towers, water coolers, oil coolers, cold water chillers, water chilling units etc.)
2. HVAC industry (Heating Ventilation Air Conditioning)
3. Pet industrial: Aquariums, fish tanks, terrariums, seafood machines, Vivariums, Paludariums, Incubators etc.
4. Medical thermostatic equipment (for blood, drugs, Pharmaceutical etc.)
5. Food processing (Brewing, Abattoirs etc.), Food Wholesale, Food Retail (Hypermarkets, Supermarkets, Convenience Stores, Food Shops, Charcuteries, Delicatessens etc.)
6. Solar water-heating system central controller
7. Sauna room, foot bath, foot sauna, foot massager etc.
8. Wine production, wine cabinet, display cabinet etc.
9. Catering (Hotels, Restaurants, etc.)
10. Agriculture
11. Automobile
12. Photography
13. Process control
14. Laboratory, Chemical
15. Greenhouses, cultivating-houses
16. Ice-skating rinks
17. Energy management
18. Other industries need temperature measuring and controlling